The Resource Comparison of implant placement accuracy using the flapless surgical technique with a conventional or stereolithographic surgical guide : a randomized clinical trial, by Aaron J. Colby, (electronic resource)

Comparison of implant placement accuracy using the flapless surgical technique with a conventional or stereolithographic surgical guide : a randomized clinical trial, by Aaron J. Colby, (electronic resource)

Label
Comparison of implant placement accuracy using the flapless surgical technique with a conventional or stereolithographic surgical guide : a randomized clinical trial
Title
Comparison of implant placement accuracy using the flapless surgical technique with a conventional or stereolithographic surgical guide
Title remainder
a randomized clinical trial
Statement of responsibility
by Aaron J. Colby
Creator
Contributor
Thesis advisor
Subject
Genre
Language
eng
Summary
The goal of this clinical investigation was to compare the accuracy of implant placement as a function of two types of surgical guides, conventional or stereolithographic, that were used with a flapless surgical technique for single implant placement in the maxillary esthetic zone. Implant placement accuracy between the treatment groups was compared by evaluating differences in the thickness of facial bone, occurrences of fenestrations or dehiscences, agreement of treatment planned and actual placed abutment, peri-implant gingival height, and peri-implant interproximal bone height. The implant failure rate over time was also evaluated. When comparing the surgical guide groups, there were no statistically significant differences between any of the evaluation outcomes Based on the study evidence, with either the conventional or stereolithographic surgical guide, implant placement accuracy was similar, as was the implant success rate over the 4-month observation period
Additional physical form
Online version of the print edition.
Cataloging source
UMK
http://library.link/vocab/creatorDate
1975-
http://library.link/vocab/creatorName
Colby, Aaron J.
Degree
M.S.
Dissertation year
2010.
Granting institution
School of Dentistry. University of Missouri--Kansas City
Illustrations
illustrations
Index
no index present
Literary form
non fiction
Nature of contents
  • dictionaries
  • bibliography
  • theses
http://library.link/vocab/relatedWorkOrContributorName
Walker, Mary P.
http://library.link/vocab/subjectName
  • Mouth
  • Flaps (Surgery)
  • Dental implants
  • Dental Implantation, Endosseous
  • Dental Implantation
  • Oral Surgical Procedures
  • Surgery, Oral
Label
Comparison of implant placement accuracy using the flapless surgical technique with a conventional or stereolithographic surgical guide : a randomized clinical trial, by Aaron J. Colby, (electronic resource)
Instantiates
Publication
Note
  • "A thesis in oral biology."
  • Advisor: Mary P. Walker
  • Typescript
  • Vita
  • Title from "catalog record" of the print edition
  • Description based on contents viewed Sept. 2, 2011
Bibliography note
Includes bibliographical references (leaves 60-64)
Carrier category
online resource
Carrier category code
  • cr
Carrier MARC source
rdacarrier.
Content category
text
Content type code
  • txt
Content type MARC source
rdacontent.
Contents
Introduction -- Materials and methods -- Results -- Discussion -- Conclusions -- Appendix 1. Consent form -- Appendix 2. Ridge mapping -- Appendix 3. Occlusal scheme -- Appendix 4. Radiographic guide -- Appendix 5. Handling instructions for the SSG -- Appendix 6. Conventional surgical guide fabrication -- Appendix 7. Abutment selection -- Appendix 8. Provisional implant restoration fabrication -- Appendix 9. Fabrication and storage of crylic measuring guide -- Appendix 10. Subject color plates
Control code
748824157
Dimensions
28 cm
Extent
  • xiii, 103 leaves
  • 1 online resource (117 pages)
Form of item
electronic
Media category
computer
Media MARC source
rdamedia.
Media type code
  • c
Other physical details
  • illustrations
  • illustrations.
Specific material designation
remote
System control number
(OCoLC)748824157
Label
Comparison of implant placement accuracy using the flapless surgical technique with a conventional or stereolithographic surgical guide : a randomized clinical trial, by Aaron J. Colby, (electronic resource)
Publication
Note
  • "A thesis in oral biology."
  • Advisor: Mary P. Walker
  • Typescript
  • Vita
  • Title from "catalog record" of the print edition
  • Description based on contents viewed Sept. 2, 2011
Bibliography note
Includes bibliographical references (leaves 60-64)
Carrier category
online resource
Carrier category code
  • cr
Carrier MARC source
rdacarrier.
Content category
text
Content type code
  • txt
Content type MARC source
rdacontent.
Contents
Introduction -- Materials and methods -- Results -- Discussion -- Conclusions -- Appendix 1. Consent form -- Appendix 2. Ridge mapping -- Appendix 3. Occlusal scheme -- Appendix 4. Radiographic guide -- Appendix 5. Handling instructions for the SSG -- Appendix 6. Conventional surgical guide fabrication -- Appendix 7. Abutment selection -- Appendix 8. Provisional implant restoration fabrication -- Appendix 9. Fabrication and storage of crylic measuring guide -- Appendix 10. Subject color plates
Control code
748824157
Dimensions
28 cm
Extent
  • xiii, 103 leaves
  • 1 online resource (117 pages)
Form of item
electronic
Media category
computer
Media MARC source
rdamedia.
Media type code
  • c
Other physical details
  • illustrations
  • illustrations.
Specific material designation
remote
System control number
(OCoLC)748824157

Library Locations

    • UMKCBorrow it
      800 E 51st St, Kansas City, MO, 64110, US
      39.035061 -94.576518
    • Health Sciences LibraryBorrow it
      2411 Holmes St, Kansas City, Kansas City, MO, 64108, US
      39.083418 -94.575323
    • Leon E. Bloch Law LibraryBorrow it
      500 E. 52nd Street, Kansas City, MO, 64110, US
      39.032488 -94.581967
Processing Feedback ...